From Energy Data to Actionable Savings

Energy Efficiency & Energy Management

Systematic assessment of how energy enters, moves through and is lost across a facility, followed by a costed, prioritised action plan.

Overview

Why this service matters

Systematic assessment of how energy enters, moves through and is lost across your facility — followed by a costed, prioritised action plan.

Our work is engineering-led. Every recommendation we issue is measured, costed and tied to a payback — not a generic checklist.

Technical Focus

What we offer

  • Engineering assessment based on field measurement
  • Baseline establishment and system performance analysis
  • Technical recommendations with cost-benefit analysis
  • Implementation roadmap and vendor evaluation
  • Measurement and Verification (M&V) of savings

Regulatory & Compliance Context

Designated Consumers notified under the Energy Conservation Act carry a statutory obligation to have energy audits conducted by an Accredited Energy Auditor at the prescribed frequency and to file the mandated returns. Non-compliance attracts penalties under the Act. Applicability, frequency and current penalty provisions should be confirmed against the notification applicable to your sector and the amendments in force.

Scope of Services

What this service covers

01

Mandatory Energy Audit

What it covers: Statutory audit for Designated Consumers under the Energy Conservation Act, 2001, conducted by an Accredited Energy Auditor, with the prescribed reporting to the State Designated Agency / BEE.
What we offer: Statutory compliance verification, formal submission preparation, and Accredited Energy Auditor sign-off.
Deliverables: BEE-compliant format energy audit report, statutory submission support.
02

Detailed Energy Audit

What it covers: Full plant-wide study covering thermal and electrical systems, energy balance, benchmarking against sectoral norms, and a ranked list of Energy Conservation Measures (ECMs).
What we offer: Plant-wide measurement, thermal and electrical mapping, ECM identification.
Deliverables: Energy audit report, energy balance and Sankey, ranked ECM register with capex, savings and payback.
03

Investment Grade Energy Audit

What it covers: Audit built to financing standard — measured baselines, bankable savings estimates, capex schedules, IRR / NPV and risk allocation. Suitable for board approval, ESCO contracting or lender appraisal.
What we offer: Bankable savings evaluation, CAPEX/OPEX analysis, and financial risk assessment.
Deliverables: Investment grade report with detailed IRR/NPV, capex schedules, and measured baselines.
04

Compressed Air System Audit

What it covers: Leak quantification, pressure profiling, specific power consumption (kW/CFM), unloading losses, artificial demand and distribution network assessment.
What we offer: Field measurements, leak detection, and specific power consumption analysis.
Deliverables: System audit report, leak quantification register, ECMs for artificial demand reduction.
05

Pumping System Performance Assessment

What it covers: Field efficiency testing, duty-point versus operating-point analysis, throttling and recirculation losses, right-sizing and VFD viability.
What we offer: Ultrasonic flow measurement, power measurement, and efficiency testing.
Deliverables: Pump performance report, VFD viability analysis, and right-sizing recommendations.
06

HVAC & Chiller System Assessment

What it covers: Chiller COP / kW-per-TR measurement, part-load performance, air- and water-side balancing, AHU and cooling tower efficiency, control strategy review.
What we offer: System performance analysis, thermal balancing, and COP measurement.
Deliverables: HVAC performance report, kW/TR assessment, and control strategy recommendations.
07

Power Quality & Harmonic Analysis

What it covers: Harmonic distortion, voltage imbalance and sag / swell profiling, power factor and reactive compensation, transformer and cable loading — and the equipment failure risk each carries.
What we offer: Power quality logging, harmonic distortion mapping, and risk assessment.
Deliverables: Power quality report, risk-rated equipment loading analysis, and mitigation roadmap.
08

Project Implementation Support & Handholding

What it covers: Technical specifications, vendor evaluation, commissioning checks and handholding through execution of approved ECMs.
What we offer: Vendor evaluation, technical specification development, and implementation roadmap.
Deliverables: Technical specifications, vendor evaluation reports, commissioning check records.
09

Measurement & Verification (M&V)

What it covers: Post-implementation savings validation against an agreed baseline, aligned with IPMVP protocol — so claimed savings can be defended to management, financiers and verifiers.
What we offer: Baseline establishment, data validation, and post-implementation measurement.
Deliverables: M&V report aligned with IPMVP protocol, verified savings documentation.

Efficient Buildings. Sustainable Tomorrow.

Let's work together to create high-performance, low-carbon assets.

Request an Audit

Deliverables

What clients receive

  • Energy audit report (BEE-compliant format where applicable)
  • Energy balance and Sankey diagrams
  • Ranked ECM register with capex, savings and payback
  • Statutory submission support
  • M&V report

Process

How we work

  1. Enquiry
  2. Scoping & Proposal
  3. Data Request / Pre-Audit
  4. Site Assessment
  5. Draft Report / Review
  6. Final Report / Presentation
  7. Implementation Support